Filter Results By:

Products

Applications

Manufacturers

Showing results: 2221 - 2235 of 2605 items found.

  • Transformer Turns Ratio Testers

    IBEKO Power AB

    Transformer turns ratio testers from TRT series are DV Power instruments mainly designed for the measurement of power transformer turns ratio. Also, they measure transformer excitation current and phase shift. Special tests, such as automatic vector group detection and magnetic balance, can be performed on three-phase transformers and three-phase autotransformers.All models, except TRT03 series, have a built-in true three-phase power source, which is necessary for testing turns ratio of transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.DV Power turns ratio testers can output various test voltages for different applications. From the extremely low test voltage of 1 V AC that enables turns ratio verification of the majority of current transformers, up to the highest test voltage of 500 V AC that provides the most accurate turns ratio testing of power transformers used in power generation and transmission. By using the external booster, test voltage increases up to 5 kV AC in order to successfully test capacitive voltage transformers.All DV Power turns ratio testers have a built-in tap changer control unit. Because of that, it is possible to control the on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, the instrument and included DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option significantly facilitates and shortens the turns ratio testing time.TRT turns ratio testers use the same set of cables as three-phase winding ohmmeter & tap changer analyzers from the TWA series. Consequently, it enables one-time cable setup for performing eight tests:turns ratioexcitation currentphase anglemagnetic balancevector group detectionwinding resistanceon-load tap changer DVtestand demagnetization.

  • Magnetizer

    345B - Oersted Technology

    The Model 300-series magnetizers are designed to handle a variety of magnetizing applications and materials, from small Alnico parts to large blocks of neodymium-iron. Each of these magnetizers feature patented ECS (Electronic Capacitance Switching) technology, which allows the user to change the capacitance of the unit through the front panel. By setting the charging voltage and capacitance of the magnetizer properly, the user can then scale the output energy of the unit to match the magnetizing fixture being used. The 300-series magnetizers also includes a peak current meter, which automatically captures the peak current of the magnetizing pulse once it occurs. A safety circuit internally discharges the capacitor banks if mains power is removed from the magnetizer or if the cabinet is opened during operation. When connected to a suitable magnetizing fixture, the magnetizer is able to disable its front panel controls if the fixture overheats. Other features include a lockout keyswitch and a current sense output jack (this connects to an oscilliscope for viewing of the magnetizing pulse). All 300-series magnetizers can be modified for computer control, photocell trigger, or autocharge operation.

  • Magnetizer

    330B - Oersted Technology

    The Model 300-series magnetizers are designed to handle a variety of magnetizing applications and materials, from small Alnico parts to large blocks of neodymium-iron. Each of these magnetizers feature patented ECS (Electronic Capacitance Switching) technology, which allows the user to change the capacitance of the unit through the front panel. By setting the charging voltage and capacitance of the magnetizer properly, the user can then scale the output energy of the unit to match the magnetizing fixture being used. The 300-series magnetizers also includes a peak current meter, which automatically captures the peak current of the magnetizing pulse once it occurs. A safety circuit internally discharges the capacitor banks if mains power is removed from the magnetizer or if the cabinet is opened during operation. When connected to a suitable magnetizing fixture, the magnetizer is able to disable its front panel controls if the fixture overheats. Other features include a lockout keyswitch and a current sense output jack (this connects to an oscilliscope for viewing of the magnetizing pulse). All 300-series magnetizers can be modified for computer control, photocell trigger, or autocharge operation.

  • Magnetizer

    350B - Oersted Technology

    The Model 300-series magnetizers are designed to handle a variety of magnetizing applications and materials, from small Alnico parts to large blocks of neodymium-iron. Each of these magnetizers feature patented ECS (Electronic Capacitance Switching) technology, which allows the user to change the capacitance of the unit through the front panel. By setting the charging voltage and capacitance of the magnetizer properly, the user can then scale the output energy of the unit to match the magnetizing fixture being used. The 300-series magnetizers also includes a peak current meter, which automatically captures the peak current of the magnetizing pulse once it occurs. A safety circuit internally discharges the capacitor banks if mains power is removed from the magnetizer or if the cabinet is opened during operation. When connected to a suitable magnetizing fixture, the magnetizer is able to disable its front panel controls if the fixture overheats. Other features include a lockout keyswitch and a current sense output jack (this connects to an oscilliscope for viewing of the magnetizing pulse). All 300-series magnetizers can be modified for computer control, photocell trigger, or autocharge operation.

  • Magnetizer

    340B - Oersted Technology

    The Model 300-series magnetizers are designed to handle a variety of magnetizing applications and materials, from small Alnico parts to large blocks of neodymium-iron. Each of these magnetizers feature patented ECS (Electronic Capacitance Switching) technology, which allows the user to change the capacitance of the unit through the front panel. By setting the charging voltage and capacitance of the magnetizer properly, the user can then scale the output energy of the unit to match the magnetizing fixture being used. The 300-series magnetizers also includes a peak current meter, which automatically captures the peak current of the magnetizing pulse once it occurs. A safety circuit internally discharges the capacitor banks if mains power is removed from the magnetizer or if the cabinet is opened during operation. When connected to a suitable magnetizing fixture, the magnetizer is able to disable its front panel controls if the fixture overheats. Other features include a lockout keyswitch and a current sense output jack (this connects to an oscilliscope for viewing of the magnetizing pulse). All 300-series magnetizers can be modified for computer control, photocell trigger, or autocharge operation.

  • Protective Bonding Testers

    RMO-E Series - IBEKO Power AB

    The RMO-E instruments are designed and ideal for testing protective bonding (grounding) of equipment following the standard IEC 61010-1. Also, they can measure the resistance of high, middle and low voltage circuit breakers, high-current bus bar joints, cable splices, and welding joints. The instruments accurately measure not only in factory environments but also in high-induction fields and substations.Both models generate a true DC ripple-free (less than 1 %) current with automatically regulated test ramps. During a test, the protective bonding testers automatically generate increasing current before measuring and decreasing current after the measurement. Consequently, this significantly decreases magnetic transients and ensures great accuracy.These instruments can store up to 500 measurements in the internal memory and have a built-in thermal printer available as an option.DV Win software communicates with the RMO-E earth resistance meter via USB or RS232 interface. It allows a user to run the test remotely from PC, as well as to download test results, analyze and generate fully configurable test reports.The RMO-E series contains two models, RMO60E and RMO100E. The main difference between these two models is in the maximal test current:60 A DC for RMO60E100 A DC for RMO100E

  • 3-Phase AC Voltage Transducer

    ENVIROMUX-PT3-600 - Network Technologies Inc

    Monitors and reports voltage of any 3 phase circuit. Remotely detect blown fuses or tripped circuit breakers. Three 600 VAC inputs, three 4-20 mA outputs. Inputs and outputs isolated from one another. Frequency: 50/60Hz. Maximum primary current: 600 volts. Accuracy: ±0.25% F.S. @60Hz. Output: 4-20 mA. "Zero" adjustment for accurate 0 VAC reading, and "Calibration" adjustment for frequency and voltage level. Powered by the ENVIROMUX-S420MA-24V. Regulatory approvals: UL, CUL, CE. Requires two ENVIROMUX-S420MA-24V to monitor three phases. Caution: installation should be performed by qualified electricians only. Make sure electrical service is disconnected before making any electrical connections.

  • Data Logger

    Ajinkya Electronic Systems

    Data Loggers are electronic instruments which capture and record data related to physical parameters like temperature, humidity, pressure, liquid flow etc. as well as electrical parameters like voltage, current etc. and reproduce them in a form suitable to the user. The reading of information, storage and reproducibility are the important parameters that define a data logger.Depending on how each of these parameters are handled data loggers can be classified in various categories and have various nomenclatures.Here are the various parameters that user can select from to choose a data logger

  • Data Logger (Category)

    Ajinkya Electronic Systems

    We have been offering to our clients a wide range of Data Logger. These are electronic instruments that capture and record data related to physical parameters, such as temperature, humidity, pressure and liquid flow. Moreover, these also record electrical parameters including voltage & current and reproduce these in suitable form for the user. The reading of information, storage and reproducibility are the important parameters that define a data logger. The various kinds of Data Loggers are different in nomenclature and are identified depending upon the how they handle the parameters.

  • Digital Indicators

    NOSHOK, INC.

    NOSHOK Digital Indicators provide local indication for pressure, level and temperature transmitters. The NOSHOK Attachable Loop Powered Digital Indicator can easily be fitted to NOSHOK pressure transmitters utilizing a 4 mA to 20 mA output signal and the Hirschmann (DIN 43650A) connector. NOSHOK also offers a dual display model that accepts a wide variety of input signals including thermocouples or RTDs, current, voltage, resistance and process signals. Plug-in option cards are available on several models for field upgrading.

  • Electrical Standards

    Fluke Calibration

    To verify the performance of an electrical calibrator or dc calibrator, you need an electrical standard. Fluke Calibration standards are found in primary calibration laboratories across the world. A wide range of electrical standards and frequency standards are designed to meet the needs of today’s laboratories for traceability and quality accreditation while also being portable, simple to use, and easy to support. Electrical standards include: Voltage standards; ac/dc transfer standards; ac measurement standards; resistance standards; ratio standards; current shunts.

  • High-Speed High-Voltage Power Amplifier

    Model 20/20C-HS - TREK, INC.

    The Model 20/20C-HS is a DC-stable, high-speed, high-voltage power amplifier used in industrial and research applications. It features an all solid- state design for high slew rate, wide bandwidth and low noise operation. The four-quadrant, active output stage sinks or sources current into reactive or resistive loads throughout the output voltage range. This type of output is essential to achieve an accurate output response and high slew rate demanded by a variety of loads such as highly capacitive or reactive loads. It is configured as a non-inverting amplifier.

  • High-Speed High-Voltage Power Amplifier

    Model 10/40A-HS - TREK, INC.

    The Model 10/40A-HS is a DC-stable, high-speed, high-voltage power amplifier used in industrial and research applications. It features an all-solid-state design for high slew rate, wide bandwidth and low-noise operation. The four-quadrant, active output stage sinks or sources current into reactive or resistive loads throughout the output voltage range. This type of output is essential to achieve an accurate output response and high slew rate demanded by a variety of loads such as highly capacitive or reactive loads. It is configured as a non-inverting amplifier.

  • Laser Diode Drivers

    Arroyo Instruments

    Arroyo Instruments offers a broad range of laser drivers to meet your exact test needs. From 100 milliamps to 100 Amps, all of Arroyo Instruments' LaserSource benchtop laser drivers include unique features not found on competing products such as optically isolated photodiode and modulation inputs, programmable PD bias, and both RS232 and USB computer interfaces. The LaserSource also has laser diode protection circuits such as interlock, ESD protection, and hardware limits for current and voltage.

  • Linear Power Supplies Voltage Stabilizer/Current Limiting, Ultra Low Ripple/Noise

    Series JQE - Kepco, Inc.

    Series JQE power supplies are systems-type voltage stabilizers with current limiting. They are available in a variety of ratings: 100 watts in a 1/4-rack package, 250-500 watts in a 1/2-rack package, and 1000 watts in a full-rack package. These power supplies offer ultra low noise and ultra low ripple at the output. They are MIL-STD-461 compliant.The traditional analog meters (M Models) have been replaced by digital meters on DM models. Availability of models with analog meters is limited and they will be discontinued in the future.

Get Help